Product Data Sheet

FISCHER & PORTER MICRO-DCI Communication Server

The Klinkmann Automation FISCHER&PORTER MICRO-DCI Communication Server (F&PM-DCI) is a Microsoft Windows application program that acts as a communication protocol Server and allows other Windows application programs to access the data from Fischer&Porter MICRO-DCI instruments (controllers). Any Microsoft Windows program that is capable of acting as a DDE, FastDDE, SuiteLink or OPC Client may use the F&PM-DCI Server.

There are following F&PM-DCI Server versions available:

- F&PM-DCI DDE & Suite Link Server (32-bit), can be used on MS Windows NT, W2K, XP and 95 (98);
- F&PM-DCI OPC & DDE Server, can be used on MS Windows NT, W2K, XP and 95 (98).

FEATURES

The OPC support for F&PM-DCI Server OPC & DDE version conforms to OPC Data Access Custom Interface Specification 2.04. The F&PM-DCI Server OPC & DDE version is tested for compliance and is compatible with OPC Foundation OPC Data Access Compliance Test Tool.

The F&PM-DCI Server DDE & Suite Link version (if running on MS Windows NT) supports the Wonderware Suite Link communication protocol.

The F&PM-DCI Server is intended for serial communication with MICRO-DCI controllers through the "Data Link" port on the instrument. Connection to the host computer is through the serial communication port of the host via an RS-422/485 adapter board or external converter. However, for 53MC5000 model controller the Server supports additional RS-232 communication channel ("Configuration" channel).

The Server supports byte stuffing: whenever 7E hexadecimal is transmitted as anything other than Start of Header (SOH), a 00 byte is inserted directly following it.

The Server minimizes system message traffic by dynamically calculating and optimizing poll lists to read only, client-requested items/points.

The Server supports multiple topics, allowing different data update rates for each controller.

The Server provides a communication status flag for each topic.

The Server supports standard DDE among multiple applications.

SPECIFICATIONS

Hardware: IBM or compatible 386/486/Pentium equipped with a minimum of 4 MB RAM (16 MB RAM for Windows NT). May require more memory to run other Windows programs simultaneously.

Software: Microsoft Windows 95 (98), Microsoft Windows NT 4.0, W2K and XP.

Maximum Connections: The Server supports up to 128 controllers connected.

F&P Devices Supported: 53MC1000, 53MC2000, 53MC4000, 53MC5000, 53SL6000, KM2000, 2340REC and 50XM1000.

Base addresses from the following table are used by the Server in order to calculate the actual addresses of the data elements in the memory of the Controller.

 
53MC1000
53MC2000
53MC4000
KM2000
53MC5000
53SL6000
2340REC
50XM1000
L
000C H 0300 H 0032 H 0032 H 0500 H 084B H 00A4 H 0021 H
B
0000 H 0200 H 0000 H 0000 H 0200 H 0800 H 0000 H 0000 H
C
0014 H 0320 H 0041 H 0041 H 0600 H 085B H 00B4 H 0025 H
H
00A1 H 0620 H 0299 H 0299 H 0F00 H 09CF H 0351 H 0052 H
A
0393 H 0393 H 1400 H 05D1 H 008E H

Accessible Point Types The following are the supported Item/Point Types:

Item name
Description
DDE Tag Type
Value Range
L
BINARY BIT Discrete 0, 1
B
Positive INTEGER Integer 0...255
C
REAL ANALOG Real 3.4*10**(-38)
... 3.4*10**(+38)
H
High precision ANALOG Real 3.4*10**(-38)
... 3.4*10**(+38)
A
TEXT STRING; 10 characters Message  
F
TEXT STRING; 5 characters Message  

The range of item/points depends on Controller type and Controller Database parameters available:

 
53MC1000
53MC2000
53MC4000
KM2000
53MC5000
53SL6000
2340REC
50XM1000
L
L000...
L063
L000...
L255
L000...
L119
L000...
L119
L000...
L999
L000...
L127
L000...
L123
L000...
L029
B
B000...
B011
B000...
B127
B000...
B049
B000...
B049
B000...
B639
B000...
B074
B000...
B163
B000...
B032
C
C000...
C046
C000...
C255
C000...
C199
C000...
C199
C000...
C639
C000...
C371
C000...
C222
C000...
C014
H
H000...
H010
H000...
H036
H000...
H049
H000...
H049
H000...
H127
H000...
H250
H000...
H127
H000...
H011
A
A000...
A009
A000...
A009
A000...
A317
A000...
A090
F
F000...
F447

Note: This table shows the Controller Database parameters available. The F&PM-DCI Server supports also the items/points outside this range, i.e. Controller all memory addresses are accessible.

The F&PM-DCI Server allows to operate with BINARY BIT (L type data) values as 8-bit (byte) or 16-bit (word) statuses. The following item/point names are used for this purpose:

Item name
Description
DDE Tag Type
Value Range
Range
E
8 bit (byte) status Integer 0...255 E000...E992
W
16 bit (word) status Integer 0...65535 W000...W992

The ranges of items/points are as follows:

 
53MC1000
53MC2000
53MC4000
KM2000
53MC5000
53SL6000
2340REC
50XM1000
E
E000...
E056
E000...
E248
E000...
E112
E000...
E112
E000...
E992
E000...
E120
E000...
E120
E000...
E024
W
W000...
W048
W000...
W240
W000...
W104
W000...
W104
W000...
W992
W000...
W112
W000...
W112
W000...
W016

ORDERING INFORMATION

Description / Order Number

F&PM-DCI DDE & Suite Link Server Manual & Disk Set / DR 020 15

F&PM-DCI OPC & DDE Server Manual & Disk Set / DR 020 16